Attic access requirement.
From the photo i see other safety trip and fall concerns such as absence of handrailing triangular treads un blocked at the inner radius and a top floor guardrail that is open and climbable permitting a child to fall through.
30 inches high 762 mm 22 inches wide 559 mm 20 feet max length 6096 mm.
If this is your first visit be sure to check out the faq.
Provide a minimum of 6 8 of headroom the entire walking length of the stairs.
Attic area exceeds 30 square feet and minimum vertical height of 30 inches measured from the top of the ceiling framing members to the bottom of the roof.
A 30 inch 762 mm minimum unobstructed headroom in the attic space shall be provided at some point above the access opening.
The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members.
The 2012 international residential code requires an attic access opening for attics with an area greater than 30 square feet and a vertical height in excess of 30 inches.
Results 1 to 23 of 23 thread.
Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches 762 mm or greater over an area of not less than 30 square feet 2 8 m 2.
The attic must be entered at a minimum by head and shoulders whether access is by pull down stairway or scuttle.
Size of scuttle and accessibility of the attic dictate the level of entry.
Attic furnace passageway minimum dimensions requirements.
The rough framed opening.