In combustible construction nearly all the codes specify that lumber or wood structural panels may be used for this purpose.
Attic draftstopping details.
Similar to fireblocking draftstopping is installed to prevent the movement of air within open building areas and is most often installed in crawl spaces attics and floor assemblies.
3 if draftstoppingis required the 1 000 sflimit applies but the divided spaces must be approximately equal.
Some codes include other draftstopping materials such as gypsum board cement fiber board or particleboard.
The babcock davis draft stop door is a non rated access door designed to provide access through draft stop spaces in the attic while preventing a back draft from one section of the attic to another.
Group r 2 occupancies not exceeding four stories in height must have combustible attic draftstopping every 3 000 square feet or above every two units whichever area is smaller.
Draftstopping is usually provided by requiring a plywood or gypsum board barrier at 3 000 ft sq intervals in attic spaces.
1 if there is no useable space above the assembly an attic or below it a crawlspace draftstoppingisn t required.
This self closing and self latching access door allows for access from both sides of the door.
2 if the assembly isn t concealed an open floor ceiling assembly above a basement draftstoppingisn t required.
Draftstopping shall be installed above and in line with sleeping unit and dwelling unit separation walls that do not extend to the underside of the roof sheathing above.
O draftstopping must be installed to subdivide concealed combustible attic spaces into areas not exceeding 3 000 sq ft draftstopping materials must comply with the following.
Multi unit housing projects are often draftstopped at specific intervals to prevent fire from jumping between adjacent units via a common attic space.
Multi family buildings generally require draftstopping in line with the dwelling units and tenant separations.
Where the assembly is enclosed by a floor membrane above and a ceiling membrane below draftstopping shall be provided in floor ceiling assemblies under the following circumstances.
Draftstopping shall divide the concealed space into approximately equal areas.
A horizontal area of 1 000 ft sq between draftstops is a typical requirement in non residential buildings in floors.
There are some points to be made about the draftstoppingrequirements.
Draftstopping is used to subdivide flooring at specific intervals and in attics and crawl spaces.