An example of this is a vaulted ceiling application framed by scissors trusses.
Attic truss bottom chord live load.
On the truss drawing will be a section which outlines all of the live and dead loads which the trusses are designed to support.
The truss shown below is known as an attic truss or a room in attic truss.
The live load shall be taken as follows.
The area of the attic where storage loads are not applied is listed as a concurrent 10 psf live load.
The remaining portions of the joists or truss bottom chords shall be designed for a uniformly distributed concurrent live load of not less than 10 lb ft2 note that in footnote b the uninhabitable attics without storage have a 10 psf non concurrent live load while this same load in footnote g i e.
In other words the truss design drawing should tell you what the truss was designed for.
20 4 10 means that the truss was designed for 20 psf top chord live load tcll 4 psf top chord dead load tcdl 0 psf bottom chord live load bcll and 10 psf bottom chord dead load bcdl.
Mike truss guy guest re.
Every truss design drawing must specify the loads that have been accounted for in the design.
A when access is provided 1500 n m 2 b when access is not provided 750 n m 2 except for maintenance ii sloping roof with slope greater than 10 degrees.
This type of truss carries a combination of roof l r or s and floor l loading in addition to the standard top and bottom chord dead loads.
In floor truss applications 2x4 or 2x3 material is typically used with the wider portion of the board resting on the bearing or what is known as a 4x2 configuration.
Analysis of an attic truss requires multiple load cases with multiple duration factors.
Lately many have also been designing for an alternate load of 20 psf in the rectangle mentioned in the previous post.
The live loads a truss is required to bear are determined by local building codes.
A the top chord and bottom chord dead load.
If the bottom chord of a roof truss functions as a floor joist such as in an attic room it carries a live load that also varies by use but a typical live floor load for a residential space is about 40 pounds per square foot.
Live loads on roof trusses.
Tcdl truss 1 65 psf 6 6 plf 2 3 3 psf 2 linoleum 1 00 psf per 1 concrete 12 0 psf 8 psf inch 1 5x8 ply 2 40 psf 0 4 1 8 total 17 05 psf tcdl 17 psf bcdl truss 1 65 psf 6 6 plf 2 3 3 psf 2 gypsum 2 00 psf 0 55 1 8.
The load on the outside of the roof.
I for sloping or flat roof with slopes up to and including 10 degrees.